Links
Home
Oracle DBA Forum
Frequent Oracle Errors
TNS:could not resolve the connect identifier specified
Backtrace message unwound by exceptions
invalid identifier
PL/SQL compilation error
internal error
missing expression
table or view does not exist
end-of-file on communication channel
TNS:listener unknown in connect descriptor
insufficient privileges
PL/SQL: numeric or value error string
TNS:protocol adapter error
ORACLE not available
target host or object does not exist
invalid number
unable to allocate string bytes of shared memory
resource busy and acquire with NOWAIT specified
error occurred at recursive SQL level string
ORACLE initialization or shutdown in progress
archiver error. Connect internal only, until freed
snapshot too old
unable to extend temp segment by string in tablespace
Credential retrieval failed
missing or invalid option
invalid username/password; logon denied
unable to create INITIAL extent for segment
out of process memory when trying to allocate string bytes
shared memory realm does not exist
cannot insert NULL
TNS:unable to connect to destination
remote database not found'>ora-02019
exception encountered: core dump
inconsistent datatypes
no data found
TNS:operation timed out
PL/SQL: could not find program
existing state of packages has been discarded
maximum number of processes exceeded
error signaled in parallel query server
ORACLE instance terminated. Disconnection forced
TNS:packet writer failure
see ORA-12699
missing right parenthesis
name is already used by an existing object
cannot identify/lock data file
invalid file operation
quoted string not properly terminated
Proliant DL740 hangs with sles8 (k_smp 2.4.21-190)

Proliant DL740 hangs with sles8 (k_smp 2.4.21-190)

2004-03-04       - By Dragos Delcea

Reply:     <<     21     22     23     24     25     26     27     28     29     30     >>  

Hello

Just a little resume of what's going on in this thread:

1-Hangs reported due to FC cards.  SOLVED with firmware upgrade.
2-Hangs suspected to be due to using framebuffer. DISABLING fmb not
tested.

I'm not using framebuffer; i selected text mode at install time. (and I would
have removed any "vga=xxx" line from grub.conf anyway)

I think that it's the keyboard & mouse switcher (also from HP) that hangs the
system, because when working from the system console, it takes about 5 minutes
to hang;

I haven't got around installing oracle to see if it hangs under stress (this
seems to me like a different problem from the one I'm having)...

Also it never  hanged when I was working from the network (as I said I have not
stressed it yet);

I am able to confirm that this "console hang" also happens with 2.4.19-304
(sp2a); (I'm using it because I want to test Secure Path from HP,and it's the
last supported one).

thnx,

dragos delcea



PS if this mail looks funny, it is because I used ms "lookout!"


3-Hangs due to asynch io. SOLVED by applying a RHEL 3.0 (on SLES8, is that
correct)?.
4-Hangs due to bad reiserfs filesystem. SOLVED with reiserfs fsck.
Correct?
5-Finally, Andrew is experiencing hangs due to high load. There is here no
FC card, but there is async io and reiserfs. Also there is a note that
taking out the broadcom cards contributes to a better uptime. This can be
a driver problem or an IO-APIC issue. Hangs not reproducible on test
system, only in production (sigh).

Do I miss something?


Best regards


Miquel Colom Piz�
Director Area T�cnica
Dept. Sistemas Hotelbeds S.L.

c-Joan Muntaner i Bordoy s/n Bjs.
07006 - Palma de Mallorca
Telf. +34 971178839
Fax. +34 971465062




"Dragos Delcea" <dragos.delcea@(protected)>
02/03/2004 10:17


       Para:   <suse-oracle@(protected)>
       cc:
       Asunto: [suse-oracle] [OT] Proliant DL740 hangs with sles8 (k_smp 2.4
.21-190)


hello,

is there someone running sles 8 on proliant dl740 ?
because randomely it hangs hard (no output message in the console or logs)
here is the setup:
HP Proliant DL740, bios P47(12/08/2003), 4CPUs 2.8GHZ, 12GB RAM, 2 fc
adapters (also from HP).

I thought installing oracle was like a walk in the park, but it seems
that there are problems...

thnx,
dragos delcea




-- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------
The content of this communication is classified as Mobifon SA Romania
Confidential and Proprietary Information.The content of this communication is
intended solely for the use of the individual or entity to whom it is addressed
and others authorized to receive it. If you are not the intended recipient you
are hereby notified that any disclosure, copying, distribution or taking any
action in reliance on the contents of this information is strictly prohibited
and may be unlawful. If you have received this communication in error, please
notify us immediately by responding to this communication then delete it from
your system. We appreciate your assistance in preserving the confidentiality of
our correspondence. Thank you.

Prezentul mesaj constituie o Informatie confidentiala si este proprietatea
exclusiva a  MobiFon S.A.. Mesajul se adreseaza numai persoanei fizice sau
juridice mentionata ca destinatara, precum si altor persoane autorizate sa-l
primeasca. In cazul in care nu sunteti destinatarul vizat, va aducem la
cunostinta ca dezvaluirea, copierea, distribuirea sau initierea unor actiuni pe
baza prezentei informatii sunt strict interzise si atrag raspunderea civila si
penala. Daca ati primit acest mesaj dintr-o eroare, va rugam sa ne anuntati
imediat, ca raspuns la mesajul de fata, si sa-l stergeti apoi din sistemul dvs.
Apreciem si va multumim pentru sprijinul acordat in pastrarea
confidentialitatii corespondentei noastre.
-- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ------